| Hi All,
How do you estimate the time frame for an open room that has neglible RT.
A particular model of mine i.e a 20,000 capacity stadium has 0 RT.
From what I know , this is quite normal when large rooms are open and EASE cannot determine the room volume due to lack of definite surfaces.
In this case, my mean free path time is 0 s.
By rule of thumb, time frame should be roughly (mean free path time * order).
When this is incalculable as in my case, how do you decide as to what would be a suitable time frame / order and no. of rays for generating a realistic reflectogram? |
|
|
|
|
Posted: Fri Aug 25, 2006 11:38 pm |
|
|
Jim Mobley |
Member |
|
|
Joined: 27 Jul 2005 |
Posts: 134 |
Location: Foothill Ranch, California, USA |
|
|
 |
|
|
| Hi Varun,
You can do a first-order Mirror Impact study and look at the arrival times in the Probe. A first order mirror calculation shouldn't take more than a minute of two. |
|
| _________________ Best regards,
Jim Mobley
Sr. Application Engineer
Renkus-Heinz, Inc.
19201 Cook St.
Foothill Ranch, CA 92610 USA
TEL: +1-949-588-9997
FAX: +1-949-588-9514
www.renkus-heinz.com
mailto:jim@renkus-heinz.com |
|
|
|