Posted: Tue May 08, 2007 7:05 pm |
|
|
jonessy |
Member |
|
|
Joined: 22 Dec 2005 |
Posts: 19 |
Location: Israel |
|
|
 |
|
|
| Hi,
Is Easera capable of performing and post-processing PET (Polar Energy/Envelope Time Curves) measurements?
Can this be done using the 'Polars' module?
If yes, then where can I find more information on using this module?
(We have the Easera Pro version through ADA foundation - which says it should include the Polars Module, but I could not find it anywhere in Easera...).
Cheers,
Jon. |
|
| _________________ --Jonathan |
|
|
|
Posted: Sat May 12, 2007 10:24 am |
|
|
Stefan |
Member |
|
|
Joined: 19 Apr 2005 |
Posts: 167 |
Location: Berlin, Germany |
|
|
 |
|
|
| Hi Jon,
at the moment so-called Polar ETC measurements are not possible with EASERA (we do have it on the todo list though!)
The Polars module hides under the button "Automation" on the Measure Tab. It should be accessible if your Help/About windows shows it.
Stefan |
|
|
|
|