Another Face Material question |
Posted: Thu Jul 09, 2009 5:43 pm |
|
|
|
| I'm modeling a basketball/court gym and I need similar material or the coefficients ofmetal building insulation R-13 faced.
Also why is it that the scattering option on the materials is always flat? |
|
|
|
|
Posted: Wed Jul 15, 2009 5:34 pm |
|
|
Jim Mobley |
Member |
|
|
Joined: 27 Jul 2005 |
Posts: 134 |
Location: Foothill Ranch, California, USA |
|
|
 |
|
|
| Hi Jordan,
The Generic, Fiberglass Insulation, Paperfaced, 3,5 inch thk.mat is probably the closest material in the database. You'll find it in American Base/Manufacturers/Generic. There's obviously a lot of this material in this room, so if you need a high degree of accuracy especially below 500 Hz., I'd suggest looking at Armstrong's website as they may have data for the plastic vapor barrier rather than the paper.
Scattering is as much a function of how a material is used as it is a property of the material. So for now, users need to assign scattering on a project-by-project basis. Easiest way to do this is to pack the project, re-open the project and then edit the local project database. |
|
| _________________ Best regards,
Jim Mobley
Sr. Application Engineer
Renkus-Heinz, Inc.
19201 Cook St.
Foothill Ranch, CA 92610 USA
TEL: +1-949-588-9997
FAX: +1-949-588-9514
www.renkus-heinz.com
mailto:jim@renkus-heinz.com |
|
|
|
Posted: Thu Jul 16, 2009 5:00 pm |
|
|
|
| Thank you for response, Jim. I was wondering, what's Armstrong's web address? |
|
|
|
|
Posted: Thu Jul 16, 2009 5:15 pm |
|
|
Jim Mobley |
Member |
|
|
Joined: 27 Jul 2005 |
Posts: 134 |
Location: Foothill Ranch, California, USA |
|
|
 |
|
|
|
| _________________ Best regards,
Jim Mobley
Sr. Application Engineer
Renkus-Heinz, Inc.
19201 Cook St.
Foothill Ranch, CA 92610 USA
TEL: +1-949-588-9997
FAX: +1-949-588-9514
www.renkus-heinz.com
mailto:jim@renkus-heinz.com |
|
|
|
Posted: Sat Nov 14, 2009 8:49 am |
|
|
melmadni |
Member |
|
|
Joined: 14 Nov 2009 |
Posts: 8 |
Location: jeddah |
|
|
 |
|
|
| I'm modeling hanger of heliport and I need similar material or the coefficients of metal building & Asphalt floor also the builing is open form one side & it had avolume of approximately 54556.67 m3 Ineed help for A suitabe Solutions. |
|
|
|
|
AFMG Network Forum Index -> EASE 4 |
You cannot post new topics in this forum You cannot reply to topics in this forum You cannot edit your posts in this forum You cannot delete your posts in this forum You cannot vote in polls in this forum
|
All times are GMT