Posted: Fri Jun 16, 2017 9:31 am |
|
|
ChrisH |
Member |
|
|
Joined: 05 Apr 2006 |
Posts: 20 |
Location: England, UK |
|
|
 |
|
|
| I've been asked by a client what standards EASE works to, but there seems to be little information given in the software literature.
As far as I can see, the following are quoted by AFMG:
• Air absorption in accordance with ISO 9613 (Part 1 presumably)
• Speech intelligibility in accordance with EN 60268-16 2011
• A-weighted mappings as per IEC 61672
Are there any others that can be quoted, for example with respect to distance attenuation / inverse square law?
Thanks!
Chris Hales |
|
|
|
|
Posted: Fri Jun 16, 2017 11:48 am |
|
|
|
| Hi Chris,
the room-acoustic standard ISO 3382
and IEC 61260 which covers octave and 1/3rd octave filters
are additionally implemented.
Frank Siegmann
AFMG |
|
|
|
|
Posted: Mon Jun 19, 2017 4:10 pm |
|
|
ChrisH |
Member |
|
|
Joined: 05 Apr 2006 |
Posts: 20 |
Location: England, UK |
|
|
 |
|
|
| Thanks Frank
Can you confirm which part of ISO3382 is implemented in EASE? I'm interested as these are primarily standards for the measurement of room acoustics, as opposed to predictions.
Regards
Chris |
|
|
|
|
Posted: Tue Jun 20, 2017 11:12 am |
|
|
|
| Hi Chris,
e.g. parameter definitions and calculation methods like impulse response integration are implemented.
Frank Siegmann |
|
|
|
|
AFMG Network Forum Index -> EASE 4 |